China New Product Design Of Rcc Structures - Net Frame, Heterosexual Structure Class – Zhenyuan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our well-equipped facilities and great good quality regulate throughout all stages of manufacturing enables us to guarantee total buyer gratification for Design Of Concrete Structures Ktu Notes, Masonry Shear Wall Design Example, Cantilever Roof Design, Let's cooperate hand in hand to jointly make a beautiful upcoming. We sincerely welcome you to pay a visit to our company or speak to us for cooperation!
China New Product Design Of Rcc Structures - Net Frame, Heterosexual Structure Class – Zhenyuan Detail:

Introduction

The basic units that make up the grid are triangular cone, triangular prism, cube, truncated quadrangle, etc. These basic units can be combined into trigons, quadrilateral, hexagons, circles or any other shape in a planar shape. It has the advantages of space stress, light weight, large rigidity, good seismic performance, etc. It can be used as the roof of gymnasium, cinema, exhibition hall, waiting hall, stadium stand awning, hangar, two-way large column grid structure and workshop.

Classification of grid:

The first type is composed of plane truss systems, which have four forms: two-way orthogonal spatial grid, two-way orthogonal sideways grid, two-way oblique sideways grid and three-way grid.

The second type is composed of quadrangular cone units, with five forms: normal quadrangular cone grid, normal evacuation quadrangular cone grid, oblique quadrangular cone grid, checkerboard quadrangular cone grid and star quadrangular cone grid.

The third category is composed of triangular cone units, with three forms: triangular cone grid, evacuated triangular cone grid and honeycomb triangular cone grid. Shell-type grid structures are mainly divided into cylindrical shell-type grid, spherical shell-type grid and hyperbolic paraboloid shell-type grid according to the form of shell surface. The grid structure is divided into steel grid, reinforced concrete grid and composite grid composed of steel and reinforced concrete according to the materials used, of which steel grid is widely used.

Internal force analysis of grid structure;

Grid structure is a high-order statically indeterminate structure system. In the analysis of plate grid, it is generally assumed that the joints are hinged, and the external load acts on the joints according to the principle of static equivalence, which can be calculated according to the space truss displacement method, i.e. the finite element method of hinged bar system. Simplified calculation methods, such as cross beam system difference analysis method and pseudo-plate method, can also be used to calculate internal forces and displacements. The joints of single-layer shell grid are generally assumed to be in rigid connections and shall be calculated according to the finite element method of rigid connections. The double-layer shell grid can be calculated by the finite element method of hinged bar system. The shell analogy method can also be used to simplify the calculation of single-layer and double-layer shell grids.

Design and structure of grid:

The bar section of the grid structure shall be calculated and determined according to the strength and stability. In order to reduce the calculated length of the compression bar and increase its stability, measures such as adding subdivided bars and supporting bars can be adopted. The joints of plate-type grid and double-layer shell-type grid made of steel mainly include cross plate joints, welded hollow spherical joints and bolted spherical joints. Cross plate joint is suitable for grid structure of section steel members. The connection between bars and joint plate is welded or high-strength bolted. Hollow spherical joints and bolted spherical joints are suitable for grid structures of steel pipe bars. The joints of single-layer shell grid structure shall be able to withstand bending internal forces. Under normal circumstances, the steel consumption of the joints accounts for about 15-20% of the steel consumption of the whole steel grid structure.

Net Frame, Heterosexual Structure Class

26

Plan of Web Bar of Grid

28

Grid Layout Plan

30

Grid Node Diagram

27

Plan of Lower Chord of Grid

29

Design Drawing of Three-Dimensional Joints of Grid


Product detail pictures:

China New Product Design Of Rcc Structures - Net Frame, Heterosexual Structure Class – Zhenyuan detail pictures


Related Product Guide:

We have now a hugely efficient team to deal with inquiries from buyers. Our goal is "100% client gratification by our solution high-quality, rate & our team service" and take pleasure in a great popularity among clients. With several factories, we will provide a wide assortment of China New Product Design Of Rcc Structures - Net Frame, Heterosexual Structure Class – Zhenyuan, The product will supply to all over the world, such as: Mombasa, Spain, Malawi, With more and more Chinese products around the world, our international business is developing rapidly and economic indicators big increase year by year. We have enough confidence to offer you both better products and service, because we are more and more powerful, professional and experience in domestic and international.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Natalie from Salt Lake City - 2018.06.28 19:27
    Problems can be quickly and effectively resolved, it is worth to be trust and working together.
    5 Stars By Liz from Zambia - 2017.01.28 19:59

    Related Products